Finally, it is necessary to regularly and regularly measure the humidity inside and outside the warehouse, as well as the wind direction, wind speed, air pressure, etc. When conditions permit, the moisture conductivity of the warehouse should also be measured to accumulate more moisture-proof test data and better grasp the moisture-proof rules of the warehouse. Only by comprehensively managing the moisture-proof calculation, building structure, meticulous construction, careful management, and moisture-proof testing of the warehouse can the moisture-proof problem of the warehouse be solved economically and reasonably.
This article comes from: http://www.zs-chsb.com/
09-12
How to choose the right conveyor assembly line?
As an efficient production method for enterprises, conveyor lines are increasingly being adopted and installed by more and more companies. So, for companies that do not have equipment or are preparing
09-12
Common faults and countermeasures analysis of bucket elevator
1. BlockageThe tail casing is filled with materials, causing the belt to slip or fail to work.reason:1) The feeding machine starts early and the elevator starts late;2) The belt slips due to lack of t
09-11
Common problems with conveyors
What are the factors causing motor overheating during conveyor operation?(1) Poor heat dissipation conditions; (2) Overloaded working hours are too long; (3) It is possible that the motor bearings a
09-11
Considerations for adjusting the feed inlet of bucket elevator
The adjustment of the feeding port should ensure that the material at the feeding port is evenly spread in the width direction to prevent uneven feeding that may cause the feeding of the bucket elevat